Patch Notes for
Version 2.1.5 of the CrossWorlds Connector for PeopleSoft

(for CrossWorlds Infrastructure versions 3.1.2.10 through 4.x.

 


The patch note contains the following sections:

CONNECTOR REVISIONS

UPGRADE INSTRUCTIONS

DOWNLOADING THE PATCH


CONNECTOR REVISIONS

This patch contains the following revisions since the last maintenance release:

Available as of Version

CR Number/APAR #

Feature

Description

2.1.1

20503/JR17957

Connector fails to delete

all the children when KEEPRELATIONS

is set to false

The same has been fixed .

2.1.2

18942/JR17957

Transactions fail with the error no. 90014 at random

 

The same has been fixed .

2.1.3

15475/ JR18435

 

 

22902/JR18435

Connector fails to come up when event component (CWEvent_CI) is missing in the application

 

Connector fails to delete specific children when KEEPRELATIONSHIP is set to false

The same has been fixed.

 

 

The same has been fixed . The delete now occurs in the reverse order to maintain indexes of the children

2.1.4

23093/JR 18683

Connector fixes needed to work against PeopleTools 8.42

Fixes done to support PeopleTools 8.42. BigDecimal support provided. For the BigDecimal support to work, at the (simple) attribute level, the application specific text should have the following added

                     :bigDec=true

As part of the PeopleSoftODA, the BO Level App-Spec Info has the following additions

:SetEditHistoryItems=true:GetDummyRows=true

 

If either of these do not need to be set for a particular BO Definition, then the value needs to be set to false for the same

 

 

2.1.5

24838/JR 18803

BigDecimal Fix for key values

Fix provided. Key attribute values are checked for BigDecimal type now.  The Application Specific Text for the key attribute should have the following added for the check to be performed

                      :bigDec=true

 


UPGRADE INSTRUCTIONS

To perform an upgrade to this version of the connector:

  1. Upgrade to the most recent maintenance (2.1.0) release if you have not already done so.
  2. Download the patch.
  3. Apply the changes prescribed in each table below, beginning with the entries at the bottom of each table and working up to the most recent patch.

Add, replace, or remove the following files and directories as indicated:

For Connector Version

Platform [WIN;UNIX]

Add / Replace / Remove

File (Starting from %CROSSWORLDS%/$CROSSWORLDS)

2.1.5

WIN;UNIX

Replace

%CROSSWORLDS%\connectors\PeopleSoft\CWPeopleSoft.jar

%CROSSWORLDS%\oda\PeopleSoft\PeopleSoftODA.jar

Add or remove the following connector properties using CSM:

For Connector Version

Platform

Add / Remove

Property (Case-Sensitive)

2.1.5 - none

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


DOWNLOADING THE PATCH

This section describes how to download the connector patch from the CrossWorlds Exchange website.

Note: Downloading software from the website requires a user name and password. Contact your CrossWorlds system administrator or a technical support contact for your site. To extract and install the connector files, you must have already installed CrossWorlds InterChange Server or Serverless Trading Agent.

To download the connector software from the Web:

  1. Back up any files that contain customized settings, for example, customized startup settings.
  2. Log in to CrossWorlds Exchange. Navigate to the Connectivity page (Support > Product Patches > Connector Patches), then expand the  appropriate ICS platform by clicking the plus sign (+) next to it.
  3. Click on the plus sign (+) next to your connector version.
  4. Find the zip file for your runtime platform, and download it.

September 20, 2001 03:44 PM

© 2001 CrossWorlds Software, Inc. Proprietary and Confidential. All Rights Reserved.