IBM® Tivoli® Compliance Insight Manager, Fix Pack 8.0.0-TIV-TCIM-FP001 README

©Copyright International Business Machines Corporation 2007. All rights reserved. U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.

NOTE: Before using this information and the product it supports, read the general information under Notices in this document.

Date: 2007 October 01


About the Fix Pack

This Fix Pack corrects problems in IBM Tivoli Compliance Insight Manager, Version 8.0.0.0. It requires that IBM Tivoli Compliance Insight Manager, Version 8.0.0.0, is installed. After installing this Fix Pack, your Tivoli Compliance Insight Manager installation will be at level 8.0.0.1.


Patch contents and distribution

This Fix Pack package contains:

This Fix Pack is distributed as an electronic download from the IBM Support Web Site.


Architectures

This Fix Pack package supports the same operating system releases as the Tivoli Compliance Insight Manager release that are listed in the Hardware and software requirements document.


Fix Packs superseded by this Fix Pack

None


Fix Pack structure

Tivoli Compliance Insight Manager supports multiple platforms, for each platform requiring updates a separate package is installed. The package will contain the updates for all components installed on that platform.


APARs and defects fixed

Problems fixed by Fix Pack 8.0.0-TIV-TCIM-FP001

The following problems are corrected by this Fix Pack. For more information about the APARs listed here, refer to the Tivoli Compliance Insight Manager support site.

APAR IZ03660
SYMPTOM: Some Windows events are not mapped or there are some inaccuracies on the mapping.

APAR IZ02804
SYMPTOM: When the User Information Source contains realnames with a length exceeding 64 characters, the load will fail.

APAR IZ03058
SYMPTOM: The version of java that is installed on the Tivoli Compliance Insight Manager systems is not aware of the new day light saving switches that are defined in the New Zealand timezone.

Internal defect PE05390
SYMPTOM: Several issues for the Tivoli Access Manager for Operating Systems Event Source (ES): The non-initial collect on AIX and HPUX fails if month day number is between 1 and 9, the active audit logfile is missed in the original sublog, "Add User Information Source" button in the Management Console is disabled for remotely audited machines, and the "successclass" is based on the wrong data field.

Internal defect PE05410
SYMPTOM: For the Oracle Event Source (ES) the event order is incorrect. This may result in 'unavailable' data fields for logoff events, when the logon and logoff occur in the same second.

Internal defect PE05470
SYMPTOM: When trying to edit a custom report with multiple "or" conditions, only one of those conditions will appear in the report editor. When the report is then saved in this state, the other (not shown) conditions are removed from the definition.

Before installing the Fix Pack

Please be aware of the following considerations before installing this Fix Pack:

Prerequisites

This Fix Pack requires that you have Tivoli Compliance Insight Manager 8.0.0 and its prerequisites installed.

Fix Pack package

The Fix Pack package is provided as an executable file for the Microsoft Windows platform and as an archive file for each supported non Windows platform.

Installing the Fix Pack

Installing the Fix Pack on Microsoft Windows

Execute the Fix Pack 8.0.0-TIV-TCIM-Win32-FP001.exe. The Fix Pack will detect any Tivoli Compliance Insight Manager components installed in the system, and will install the updates for the detected components.

NOTES

Installing the Fix Pack on AIX

To apply the Fix Pack for Tivoli Compliance Insight Manager Actuator for AIX, follow these steps:

  1. Transfer the 8.0.0-TIV-TCIM-AIXPPC32-FP001.tar.gz to a temporary directory on the AIX system, via FTP in binary mode.
  2. Decompress the upgrade package:
    # gzip -dc 8.0.0-TIV-TCIM-AIXPPC32-FP001.tar.gz | tar xvf -
  3. Apply the Fix Pack package, (The default installation directory is assumed.)
    # ./apply.sh /usr/lpp/Consul/eprise/actuator
  4. Verify that the Actuator agent has started by inspecting the list of active processes:
    # ps -ef | grep agent

    Note:
    Only one instance of the Actuator agent should be active.

Installing the Fix Pack on Solaris

To apply the Fix Pack for Tivoli Compliance Insight Manager Actuator for Solaris, follow these steps:

  1. Transfer the 8.0.0-TIV-TCIM-SolarisSparc-FP001.tar.gz to a temporary directory on the Solaris system, via FTP in binary mode.
  2. Decompress the upgrade package:
    # gzip -dc 8.0.0-TIV-TCIM-SolarisSparc-FP001.tar.gz | tar xvf -
  3. Apply the Fix Pack package, (The default installation directory is assumed.)
    # ./apply.sh /opt/CRMNceaac
  4. Verify that the Actuator agent has started by inspecting the list of active processes:
    # ps -ef | grep agent

    Note:
    Only one instance of the Actuator agent should be active.

Installing the Fix Pack on HP-UX

To apply the Fix Pack for Tivoli Compliance Insight Manager Actuator for HP-UX, follow these steps:

  1. Transfer the 8.0.0-TIV-TCIM-HPUXPARISC-FP001.tar.gz to a temporary directory on the HP-UX system, via FTP in binary mode.
  2. Decompress the upgrade package:
    # gzip -dc 8.0.0-TIV-TCIM-HPUXPARISC-FP001.tar.gz | tar xvf -
  3. Apply the Fix Pack package, (The default installation directory is assumed.)
    # ./apply.sh /opt/consul/actuator
  4. Verify that the Actuator agent has started by inspecting the list of active processes:
    # ps -ef | grep agent

    Note:
    Only one instance of the Actuator agent should be active.
h


Documentation updates

None


Software limitations

Installing a component after installing the Fix Pack

If you install a Tivoli Compliance Insight Manager component to the system after the Fix Pack has been applied, you must reinstall the Fix Pack on that system, so that all components are at the same level.


Known problems and workarounds

None.


Notices

This information was developed for products and services offered in the U.S.A. IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-IBM product, program, or service. IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to:

IBM Director of Licensing
IBM Corporation
North Castle Drive
Armonk, NY 10504-1785
U.S.A.

For license inquiries regarding double-byte (DBCS) information, contact the IBM Intellectual Property Department in your country or send inquiries, in writing, to:

IBM World Trade Asia Corporation
Licensing
2-31 Roppongi 3-chome, Minato-ku
Tokyo 106, Japan

The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law: INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions; therefore, this statement may not apply to you.

This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.

Any references in this information to non-IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk.

IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.

Licensees of this program who wish to have information about it for the purpose of enabling: (i) the exchange of information between independently created programs and other programs (including this one) and (ii) the mutual use of the information that has been exchanged, should contact:

IBM Corporation
2Z4A/101
11400 Burnet Road
Austin, TX 78758
U.S.A.

Such information may be available, subject to appropriate terms and conditions, including in some cases, payment of a fee.

The licensed program described in this document and all licensed material available for it are provided by IBM under terms of the IBM Customer Agreement, IBM International Program License Agreement or any equivalent agreement between us.

Any performance data contained herein was determined in a controlled environment. Therefore, the results obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurement may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment.

Information concerning non-IBM products was obtained from the suppliers of those products, their published announcements or other publicly available sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products.

All statements regarding IBM's future direction or intent are subject to change or withdrawal without notice, and represent goals and objectives only.

This information contains examples of data and reports used in daily business operations. To illustrate them as completely as possible, the examples include the names of individuals, companies, brands, and products. All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental.


Trademarks

The following terms are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both:

AIX
IBM
IBM logo
iSeries
pSeries
S/390
Tivoli
Tivoli logo
xSeries
zSeries

Adobe, Acrobat, Portable Document Format (PDF), and PostScript are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States, other countries, or both.

Java and all Java-based trademarks and logos are trademarks of Sun Microsystems, Inc. in the United States, other countries, or both.

Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both.

UNIX is a registered trademark of The Open Group in the United States and other countries.

Other company, product, and service names may be trademarks or service marks of others.