IBM Rational Manual Tester, Version 7.0.0.2 Readme

© Copyright International Business Machines Corporation 2004, 2007. All rights reserved. US Government Users Restricted Rights - Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.

Contents

1.0 About this release
2.0 Installation information
3.0 Fixes contained in this release
   3.1 Pasting into a group causes icons to disappear
   3.2 Image deletions from a script are not saved
   3.3 When resizing multiple images in a script, the new size may not be saved
   3.4 With multiple undos of Add to Group, the Authoring Editor and Outline view can get out of synch
   3.5 RMT Tours do not work in 4 languages (localized Windows only)
   3.6 Dragging from Reuse view and then undoing may make Authoring Editor and Outline view out of synch
   3.7 Imported scripts may not be fully visible in the Authoring Editor
   3.8 Citrix environment: After install, run Manual Tester once as administrator
4.0 Known limitations, problems and workarounds
   4.1 See Manual Tester 7.0
   4.2 The rollback feature is not supported in Installation Manager Version 1.0.0.2 and 1.0.0.3
   4.3 Error when stopping a manual test run that was started from CQTM
   4.4 Manual test log generated through CQTM does not contain captured images
   4.5 Scripts imported from Test Manager contain extra spaces in groups; affects cut/copy and paste
   4.6 After running a manual test script in CQTM, Manual Tester toolbar buttons disappear
   4.7 Cannot export multiple manual test scripts at once
   4.8 When pasting on top of existing statements in the authoring editor, paste does not work properly
   4.9 Manual Tester might crash when you select text in a table cell
   4.10 Avoid getting the Run Test Script window into a hybrid state
   4.11 When Manual Tester 6.1.x and 7.0 are installed on the same computer, problems with 6.1.x
   4.12 Windows Vista: Rational Test Manager not supported
   4.13 Windows Vista nonadmin users: Opening test scripts from the file system opens multiple instances of Manual Tester
   4.14 Windows Vista nonadmin users: Manual Tester gives an error when launched the first time
   4.15 New Microsoft Office 2007 file types (Word or Excel) are not supported for import
   4.16 Windows Vista: Samples Gallery and Tutorials Gallery do not support the high resolution setting
   4.17 Windows Vista Japanese: Samples Gallery and Tutorials Gallery require Mozilla Firefox as the supported Web browser
5.0 IBM Rational software support
6.0 Notices and trademarks

1.0 About this release

The latest version of this document is available at the following Web site:
http://download.boulder.ibm.com/ibmdl/pub/software/rationalsdp/v7/rmt/7002/docs/readme/readme.html

This file is available in the following national languages:

Brazilian Portuguese Chinese — Simplified Chinese — Traditional
French German Italian
Japanese Korean Spanish

This release fixes a number of known issues with releases 7.0 and 7.0.0.1 of IBM® Rational® Manual Tester. For more details, see section 3.0 later in this document.  This release also includes national-language editions of the help system for supported languages. 

In addition, see the release notes for version 7.0 of this product to learn about its new features and any limitations or problems known at the time of its release. The release notes for version 7.0 are available at: http://download.boulder.ibm.com/ibmdl/pub/software/rationalsdp/v7/rmt/70/docs/readme/readme.html

2.0 Installation information

This section describes the installation requirements and specific installation instructions for this fix pack.

For information about installing Rational Manual Tester, Version 7.0, including installation prerequisites, see the installation instructions online at http://download.boulder.ibm.com/ibmdl/pub/software/rationalsdp/v7/rmt/70/docs/install_instruction/install.html.
These instructions were last updated for the 7.0.0.1 release.

Prerequisites

Before you can install this fix pack, you must update your Installation Manager to version 1.0.0.3. Whenever you use Installation Manager to update an installed package, it automatically updates itself if necessary. For additional information about Installation Manager, Version 1.0.0.3, refer to http://download.boulder.ibm.com/ibmdl/pub/software/rationalsdp/v7/im/1003/docs/readme/readme.html.

Installation

The following are two common ways to install this fix pack:

  1. If Manual Tester, version 7.0 or 7.0.0.1 is already installed on your system, then you can install this update using the Update Packages wizard in IBM Installation Manager. For general instructions on installing an update, refer to the section "Updating Rational Manual Tester" in the Installation Guide.
  2. If you are installing Manual Tester, Version 7.0 for the first time, then you can install this update at the same time that you install Manual Tester 7.0. When you run the Installation Manager, click Check for updates on the Install page of the Install Packages wizard.

For general instructions on installing an update, refer to the section "Installing IBM Rational Manual Tester by using the IBM Installation Manager graphical interface" in the Installation Guide.


Installing on Windows Vista

This release supports Windows® Vista Business, Enterprise, and Ultimate editions. For more information about Vista support for all Rational products, please visit http://www-1.ibm.com/support/docview.wss?uid=swg21250765.

The steps for installing Rational Manual Tester on Windows Vista are generally the same as for Windows XP, with the following notes:

Starting the application on Windows Vista
If you select either an installation location or shared resources directory within the Program Files directory, then you must also start Manual Tester for the first time as administrator. For more information on running Rational Manual Tester on Windows Vista, refer to the technote at http://www.ibm.com/support/docview.wss?uid=swg21257842

Important note about upgrading from Microsoft Windows XP to Windows Vista
If you plan to upgrade your Microsoft Windows XP operating system to Windows Vista and IBM Rational Manual Tester, Version 7.0 or 7.0.0.1 is currently installed, refer to the instructions on the Support Web site, http://www.ibm.com/support/docview.wss?uid=swg21257411.

 

3.0 Fixes contained in this release

The following fixes are included in this fix pack:

3.1 Pasting into a group causes icons to disappear

3.2 Image deletions from a script are not saved

3.3 When resizing multiple images in a script, the new size may not be saved

3.4 With multiple undos of Add to Group, the Authoring Editor and Outline view can get out of synch

3.5 RMT Tours do not work in 4 languages (localized Windows only)

On localized Windows operating systems, the tours now display properly in all supported languages. In Simplified Chinese, the tour displays in English.

3.6 Dragging from Reuse view and then undoing may make Authoring Editor and Outline view out of synch

3.7 Imported scripts may not be fully visible in the Authoring Editor

This note refers to scripts migrated from version 6.1.x. These now display properly.

3.8 Citrix environment: After install, run Manual Tester once as administrator

This step is no longer necessary.

4.0 Known limitations, problems, and workarounds

This section describes known limitations and problems specific to this release, and any workarounds that are available.

4.1 See Manual Tester 7.0

For information about known limitations, problems, and workarounds for version 7.0, please refer to the release notes for Manual Tester, Version 7.0: http://download.boulder.ibm.com/ibmdl/pub/software/rationalsdp/v7/rmt/70/docs/readme/readme.html

4.2 The rollback feature is not supported in Installation Manager Version 1.0.0.2 and 1.0.0.3

Contrary to the Installation Manager online help and 7.0.0.1 product Installation Guide documents, you cannot use the Uninstall Packages wizard rollback feature; the rollback feature is not supported in Installation Manager Version 1.0.0.2 and 1.0.0.3 (the current version).

The Rolling back updates online help topic indicates that you can use the Uninstall Packages wizard to revert to a previously installed version of a package. For example, if you install Rational Manual Tester 7.0 and then update to version 7.0.0.2, the help topic states that you can use the rollback feature to revert to 7.0; this is not possible. Also, the Silent Install Commands online help topic indicates that you can use a rollback command during silent install; this command is not supported.

Workaround: In order to revert back to an earlier version of a package, you must uninstall the entire package; a single uninstall removes the 7.0 and upgraded package. In the example, you would need to uninstall 7.0.0.2 and then reinstall the 7.0 package.

4.3 Error when stopping a manual test run that was started from CQTM

This occurs when you run and then stop a test case from ClearQuest® Test Manager that contains a manual test script. If you close Manual Tester after the Run Test Script window opens, you will see a null pointer exception (Java® error).  To avoid the error, be sure to click Apply a couple of times in the Run Test Script window before stopping the test or exiting the Run Test Script window. 

4.4 Manual test log generated through CQTM does not contain captured images

When you run a manual test using ClearQuest Test Manager, and you capture images using the Run Test Script window during the test, these images are not saved to the manual test log. If you require images in the test log, you should run the test directly from Manual Tester.

4.5 Scripts imported from Test Manager contain extra spaces in groups; affects cut/copy and paste

When you import scripts from Test Manager into Manual Tester, an extra space is added at the end of a group statement. The space is not noticeable, except if you want to cut or copy and paste the group in Manual Tester. If you fail to select the space when selecting the group for copying, you won't copy the whole group, including substatements, as expected.

You can either delete the spaces in the imported script, or just remember to drag all the way to the right when selecting a group statement to ensure you pick up the space character.

4.6 After running a manual test script in CQTM, Manual Tester toolbar buttons disappear

Certain buttons on the Manual Tester toolbar, including Undo and the text-editing buttons (Bold, Underline, and so forth) disappear after you run a test case in ClearQuest Test Manager that includes a manual test. When the test is complete and you switch from ClearQuest mode to authoring mode, the toolbar buttons are no longer visible. You can still use these functions via the Edit menu. Or, to bring back the buttons, restart Manual Tester.

4.7 Cannot export multiple manual test scripts at once

The ability to export multiple manual test scripts to CSV at once is not working. You must export each script separately.

4.8 When pasting on top of existing statements in the authoring editor, paste does not work properly

When you select an existing statement and then paste one or more statements on top of it, the paste operation does not work as expected:

In both cases, it is better to delete the unwanted statement(s) first, and then paste the new statements.

4.9 Manual Tester might crash when you select text in a table cell

If you select some text in a table cell within a manual test script, Manual Tester may crash, especially if you select text across multiple cells. If you encounter this problem, try to use keyboard functions such as Insert and Delete to make your changes rather than selecting text.

4.10 Avoid getting the Run Test Script window into a hybrid state

Certain actions while running a test script may cause the Run Test Script window to get into a "hybrid" state, with some functions of the authoring editor available. It is best to avoid getting into this state. Here are some recommendations:

If you find that Manual Tester does get into this state, you can fix it by deleting your Manual Tester workspace. This directory is automatically created by Manual Tester and stores data such as window position, size, etc. If you delete it, you will lose your window customizations but no critical data. The directory is C:\Documents and Settings\<user name>\IBM\RMT7.0\workspace

4.11 When Manual Tester 6.1.x and 7.0 are installed on the same computer, problems with 6.1.x

When Manual Tester 6.1.x and 7.0 are installed on the same computer, you may see some nonsense values in the Execution Results when running scripts in version 6.1.x. In version 6.1.x, you can delete the nonsense execution results (using the Preferences dialog box), taking care not to delete the four default results (error, fail, inconclusive, and pass).

4.12 Windows Vista: Rational Test Manager not supported

IBM Rational Test Manager is not currently supported on Windows Vista operating systems. Users who rely on this software should avoid upgrading to Vista at this time.  

4.13 Windows Vista nonadmin users: Opening test scripts from the file system opens multiple instances of Manual Tester

On the Windows Vista operating system only, if you are logged in as a nonadmin user and open manual test scripts from the file system (for example, by double-clicking the files in Windows Explorer), you will start multiple instances of Manual Tester. These instances cannot work together: you cannot copy text from one to another, for example. You should open your test scripts from within Manual Tester, using the File>Open command or the Recent Files view.

4.14 Windows Vista nonadmin users: Manual Tester gives an error when launched the first time

On the Windows Vista operating system, you must run the Manual Tester installation as an administrator. Belonging to an administrator group is not sufficient. For more information about installation on Windows Vista, see the notes in the Installation section above.

You should also run the application once as an administrator. Navigate to and right-click the file, located in your Manual Tester installation directory under RMT7.0\rtmt.exe, and select Run as administrator. If a nonadmin user launches Manual Tester for the first time after installation, he or she will see an error with no explanation: "An error has occurred. See the log file..."

4.15 New Microsoft Office 2007 file types (Word or Excel) are not supported for import

Manual Tester cannot import files saved in the new Office 2007 file formats.

4.16 Windows Vista: Samples Gallery and Tutorials Gallery do not support the high resolution setting

The Samples Gallery and Tutorials Gallery do not support the new high resolution display setting "Larger scale(120DPI)- make text more readable" on the Windows Vista operating system. The gallery content does not display if this option is set. If you changed to the new high resolution display option, change to a lower resolution setting (for example, the default 90 DPI setting).
To change this setting, follow these steps:
1. Open the Control Panel.
2. Click Ease of Access Center > Make Computer easier to see > Change the size of text and icons.
3. Select  90 DPI (the default setting).
4. Click Save settings.

4.17 Windows Vista Japanese: Samples Gallery and Tutorials Gallery require Mozilla Firefox as the supported Web browser

On the Japanese version of the Windows Vista operating system, the Samples Gallery and Tutorials Gallery require Mozilla Firefox as the Web browser preference;  the gallery content does not display on other Web browsers. To use these galleries, install Mozilla Firefox, and then set the Web Browser preference (click Window > Preferences > General > Web Browser) to Mozilla Firefox.

5.0 IBM Rational software support

IBM Rational Software Support provides you with technical assistance.

For contact information and guidelines or reference materials that you will need when you require support, read the IBM Software Support Handbook.

For FAQs, lists of know problems and fixes, and other support information, visit the IBM Rational Manual Tester Software Support Web site.

For Rational software product news, events, and other information, visit the IBM Rational Software Web site.

Before you contact IBM Rational Software Support, gather the background information that you will need to describe your problem. When describing a problem to an IBM software support specialist, be as specific as possible and include all relevant background information so that the specialist can help you solve the problem efficiently. To save time, know the answers to these questions:

6.0 Notices and trademarks

© Copyright IBM Corporation 2004, 2007.

U.S. Government Users Restricted Rights - Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.

This information was developed for products and services offered in the U.S.A. IBM may not offer the products, services, or features discussed in this documentation in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-IBM product, program, or service.
IBM may have patents or pending patent applications covering subject matter described in this documentation. The furnishing of this documentation does not give you any license to these patents. You can send license inquiries, in writing, to:
IBM Director of Licensing
IBM Corporation
North Castle Drive
Armonk, NY 10504-1785
U.S.A.

For license inquiries regarding double-byte (DBCS) information, contact the IBM Intellectual Property Department in your country or send inquiries, in writing, to:
IBM World Trade Asia Corporation
Licensing
2-31 Roppongi 3-chome, Minato-ku
Tokyo 106, Japan


The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law:

INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you.

This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.

Licensees of this program who wish to have information about it for the purpose of enabling:
(i) the exchange of information between independently created programs and other programs (including this one) and (ii) the mutual use of the information which has been exchanged, should contact:
Intellectual Property Dept. for Rational Software
IBM Corporation
20 Maguire Road
Lexington, Massachusetts 02421-3112
U.S.A.


Such information may be available, subject to appropriate terms and conditions, including in some cases, payment of a fee.

The licensed program described in this documentation and all licensed material available for it are provided by IBM under terms of the IBM Customer Agreement, IBM International Program License Agreement or any equivalent agreement between us.

Any performance data contained herein was determined in a controlled environment. Therefore, the results obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurements may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment.

Information concerning non-IBM products was obtained from the suppliers of those products, their published announcements or other publicly available sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products.

All statements regarding IBM's future direction or intent are subject to change or withdrawal without notice, and represent goals and objectives only.

Trademarks and service marks

The following terms are trademarks of International Business Machines Corporation in the United States, other countries, or both:

ClearQuest
IBM
Rational

Java and all Java-based trademarks are trademarks of Sun Microsystems, Inc. in the United States, other countries, or both.

Microsoft and Windows are trademarks of Microsoft Corporation in the United States, other countries, or both.

Other company, product or service names, may be trademarks or service marks of others.