CICS CLIENTS Version 2.0.4 service level 6


The following table shows the APARs that are fixed by

service pack 06 , what platform they were raised on,

and what platform they fix :



Platform that the APAR was raised on

|   APAR number

|    |    Applicable to Dos

|    |    | Applicable to Windows

|    |    | | Applicable to OS/2

|    |    | | | Applicable to Windows 95

|    |    | | | | Applicable to Windows NT

|    |    | | | | |              APAR Description

|    |    | | | | |              |

V    V    V V V V V              V

N PQ12067 D W O 9 N EPIGETEVENT CAUSES CCL3101 + BAD INDEX

9 PQ13547   W O 9 N CORRUPTED FIELD OBJECT VISUAL BASIC,C++

D PQ02173 D W       REPEATED PRINTLINE GIVES EXTRA FORMFEED

9 PQ12285 D W O 9 N PAGE FAULT ON CCLTERMINAL DISCONNECT

9 PQ12740 D W O 9 N 2ND SERVER DOESN'T START IF 2 DEFINED

N PQ13454       9 N MINIMIZED CICSPRNT WINDOWS POPUP

N PQ13788 D   O 9 N SOME CICSPRNT TERMINALS DO NOT RESTART



PQ12067

****************************************************************

* USERS AFFECTED: Users of EPI                                 *

****************************************************************

* PROBLEM DESCRIPTION: When the server goes down and there is  *

*                      nothing running on an EPI terminal,     *

*                      the terminal is not deleted.            *

****************************************************************

* RECOMMENDATION:                                              *

****************************************************************

When the server goes down and there is nothing running on an EPI

terminal, the terminal is not deleted. This means that the

terminal cannot be reused to connect to a second server.



----------------  Problem conclusion

The CICS client has been changed so that EPI terminals are

always cleaned up when the server goes down. An EPIAddTerminal

can then be issued for the terminal to another server.



PQ13547

****************************************************************

* USERS AFFECTED: users of Visual Basic OLE EPI and C++        *

*                 EPI classes                                  *

****************************************************************

* PROBLEM DESCRIPTION: Text contents of C++ Cclfield and       *

*                      Visual Basic Ccl.Field objects          *

*                      corrupted.                              *

****************************************************************

* RECOMMENDATION:                                              *

****************************************************************

A CICS Server sends a 3270 data stream to the client where

some fields have the MDT flag set.If the fields with MDT set

are not immediately preceded by a set buffer address command

the text contents of the fields are corrupted when accessed

using the CICS Client Cclfield and Ccl.Field methods.



----------------  Problem conclusion



The client has been modified so that it will correctly

process data streams which contain Modify Field commands

which are not immediately preceded by a Set Buffer Address

                                                                                                                      command.



PQ02173

****************************************************************

* USERS AFFECTED: Users of the IBM CICS Version 2.0 Client     *

*                 for Windows and Dos printer terminals        *

****************************************************************

* PROBLEM DESCRIPTION: Formfeeds are appended to EXEC CICS     *

*                      SEND PRINT commands by the printer      *

*                      terminal .                              *

****************************************************************

* RECOMMENDATION:                                              *

****************************************************************

An EXEC CICS SEND PRINT is issued on a server to a client

printer terminal . Under Dos and Windows 3.1 this always

results in a formfeed being issued . This is incorrect since

a formfeed should only occur if the FORMFEED option was

specified in the EXEC CICS SEND PRINT .



----------------  Problem conclusion

The IBM CICS Clients for DOS and Windows 3.1 have been modified

to stop the extra formfeeds and make them consistent with

the IBM CICS Clients for OS2, Windows NT and Windows 95.

If the user wishes to put formfeeds after SENDs

they can specify the FORMFEED option in the EXEC CICS SEND

PRINT. This APAR only effects output resulting from an

EXEC CICS SEND PRINT. If a user invokes print screen via

the keyboard then a formfeed will still be appended.



PQ12285

****************************************************************

* USERS AFFECTED: Users of client terminals (including         *

*                 EPI).                                        *

****************************************************************

* PROBLEM DESCRIPTION: Invalid Page fault at 00407763 during   *

*                      terminal deletion.                      *

****************************************************************

* RECOMMENDATION:                                              *

****************************************************************

The client invalidly references the representation of the

terminal control block after it has been deleted. This

can lead to invalid storage being referenced and a page fault

occurring.



----------------  Problem conclusion



The client has been changed so as to not reference freed

storage.



PQ12740

****************************************************************

* USERS AFFECTED: Users of multiple netbios servers.           *

****************************************************************

* PROBLEM DESCRIPTION: The client cannot connect to 2 netbios  *

*                      servers.                                *

****************************************************************

* RECOMMENDATION:                                              *

****************************************************************

The user cannot connect to 2 netbios servers. The client

trace shows that the netbios call to the 2nd server gets

a return code 7.



----------------  Problem conclusion



The client has been changed so that the rcbs used to call

netbios are on a 4 byte boundary. This prevents the Microsoft

netbios returning the bad return code.



PQ13454

****************************************************************

* USERS AFFECTED: All users of the CICS client for Windows/NT  *

****************************************************************

* PROBLEM DESCRIPTION: Windows redrawn on reconnection.        *

****************************************************************

* RECOMMENDATION:                                              *

****************************************************************

A minimized CICSPRNT window is redrawn upon client

reconnecting to server.



----------------  Problem conclusion



The CICS client has been modified to not redraw CICSPRNT

windows when the server it connects to restarts.



PQ13788

****************************************************************

* USERS AFFECTED: All users of CICS client                     *

****************************************************************

* PROBLEM DESCRIPTION: If more client terminals are active     *

*                      than the value of MaxRequests in        *

*                      CICSCLI.INI, then upon shutting         *

*                      down and restarting the server, only    *

*                      some terminals will be reconnected.     *

*                      The rest will disappear.                *

****************************************************************

* RECOMMENDATION:                                              *

****************************************************************

If more terminals are used than the setting of MaxRequests

in CICSCLI.INI, then upon losing and regaining a connection

to the server the client will only reconnect the same

number of terminals as the value of MaxRequests.



----------------  Problem conclusion



CICSPRNT has been modified to correct this behaviour.



Click here to download the latest PTF's.