Product: CallPath Switch Server/2 for Nortel Meridian 1 Version: 2.02 Package Name: sl1s1950.exe Size: 815363 (796Kb) Level: 1950 How to install: download the self extracting file, sl1s1950.exe, or sles1950.exe, to a temporary directory. Run it from any command line and follow the prompts. Select the appropriate directory, depending on whether you have downloaded the ethernet or the non-ethernet version of the software If you answered "Yes" to the backup query and wish to undo the service update, issue the following commands: : cd \ -Qdr where is the drive the product is installed on, and is the full path of the backup self-extracting file. Fixes: INTERNAL 4870 Symptom: If SS/2 is installed on a machine which has had a CallPath Server installed, the startup.cmd file will overwrite the CallPath startup lines and put multiple SS/2 startup lines in the startup.cmd file Problem: The SS/2 install program searched for an incorrect set of characters in the file to determine if it needed to insert a command to start SS/2. Solution: The install program was changed to search for a more definitive string to determine whether or not to insert the start command. INTERNAL 5131 Symptom: The SS/2 backup procedure did not successfully back up the SS/2 system. Problem: The SS/2 backup procedure attempted to back up the entire SS/2 system to diskette and due to the increase size of the system, it would not fit. Solution: The SS/2 backup procedure was modified to be consistent with the new Installshield install procedure. The entire system is no longer backed up, only the configuration files. The backss2.cmd was replaced with the instcfg.cmd. INTERNAL 5706 Symptom: Certain libraries could not be found when executing SS/2. Problem: The c:\cpss2 path was being put at the end of libpath. If libpath was too long, the SS/2 libraries weren't found. Solution: Put c:\cpss2 path at beginning of libpath. INTERNAL 5708 Symptom: Attempts to configure a switch failed. Problem: The galaxy dll which is used during the configuration was not being installed onto disk properly. Solution: The SS/2 install procedure was changed to insure the dll was placed in it's expected path on disk. APAR IC27662 not be processed. This it turn would cause inacurrate CallPath events to flow. Condition would last for several minutes. APAR IC27665 the meridian link. Inaccurate meridian link messages are generate which causes callstate model corruption. APAR IC27666 APAR IY13757 cause a hang in switch.exe. This only occurs on a Windows NT operating system. APAR IC28315 representative for more informatiom. Files in service: cpss2\readme.txt cpss2\asn1.dll cpss2\hm.exe cpss2\libasn1a.dll cpss2\libcmnr.dll cpss2\libpicom.dll cpss2\ss2sdevt.msg cpss2\csauiswm.exe cpss2\csm.exe cpss2\prodinfo.msg cpss2\cfgswx.eus cpss2\switchx.exe Ethernet file: cpss2\switchse.exe