Final Release of Patch V86F-3 Only applicable to V86F-1 Code Build Stream Pre-requisite patch V86F-2 must be installed prior to this patch. ********************* IBM CORPORATION – DISCLAIMER ****************** * In accordance to IBM's commitment to maintain the highest level of * * customer satisfaction, this patch is being provided to customers * * who have purchased the referenced IBM StorWatch MSS Specialist * * product that is currently covered by one of IBM's extensive warranty * * plans and is also provided to those customers not yet under IBM's * * extended warranty plan as a courtesy. The availability of this patch * * is in no way an obligation by IBM to continue this practice in the * * future. * ************************************************************************ ****************************** WARNING ******************************** * * * - Please be sure to cut and paste EXACTLY as indicated. Any * * addition or subtraction of pertinent patch data will mean the * * patch will not load due to a checksum failure and the controller * * will remain at it's original version. * * * * - As always, any critical data should be backed up prior to * * performing any updates. * *********************************************************************** PATCH V86F-3 Patch Title: Sparing size, Save_Configuration, UA buffer loss HSOF Version: MSS RAID Controllers (HSG80 V86 / HSG60 V86) Patch Number: 3 Date: 19-Sept-2001 I. Patch Description: Problem Symptoms: 1. Storage units containing Save_Configuration data written by an MSS Control Module (ACS) version prior to V86 will be shown as existing by V86, and presumably is valid (which it is not). 2. A replacement disk drive of equal capacity to a failing drive can not be used as the spare if the the drive involved has Save_configuration data written by a prior to a V86 version of MSS Control Module (ACS) on that drive/unit. 3. MSS RAID IBM StorWatch MSS Specialist (HSG80) crash with LFC 02F60103 and 43130100. Background: Metadata region was required to expand due to V86 functionality enhancements. Resolution: 1. When storage unit is discovered to have an old version of metadata area allocated, the metadata will be invalidated so that the old Save_Configuration data disappears. 2. Doing solution #1, resolves the capacity issue during spare device replacements for failed drives. 3. This patch will ensure that MSS RAID IBM StorWatch MSS Specialist (HSG80) handle UA traffic and prevent buffer loss. Title: Sparing size, Save_Configuration, UA buffer loss Version: V86F Length: 158 Patch Type: 0 Patch Number: 3 Count: 1 Address: C004708C Value[ 0]: 08000050 Count: 2 Address: C0075020 Value[ 0]: 84003000 Value[ 1]: C0FFF3B8 Count: 1 Address: C00A69E8 Value[ 0]: 08000014 Count: 3 Address: C00D07F0 Value[ 0]: 80A5A0B3 Value[ 1]: 59ABDE03 Value[ 2]: 59A50E18 Count: 1 Address: C00D0DCC Value[ 0]: 59ABDE03 Count: 2 Address: C00D6D6C Value[ 0]: 84003000 Value[ 1]: C0FFF3D4 Count: 17 Address: C0FFF3B8 Value[ 0]: 90A420C8 Value[ 1]: 58A50E0E Value[ 2]: 92A420C8 Value[ 3]: 8CA57400 Value[ 4]: FFFFFE0C Value[ 5]: 84003000 Value[ 6]: C0075028 Value[ 7]: 80A560B3 Value[ 8]: 3205200C Value[ 9]: 59A50901 Value[ 10]: 82A560B3 Value[ 11]: 90A56088 Value[ 12]: 3205200C Value[ 13]: 84003000 Value[ 14]: C00D6D74 Value[ 15]: 84003000 Value[ 16]: C00D6D80 Count: 0 Verification: CEB4D779 II. Patch Installation Script for use with a host to CLI Utility Extract the following script to file PATCH_V86F-3.script. Submit script to CCL via Command Scripter utility. ----- Begin Script ----- ! !Sparing size, Save_Configuration, UA buffer loss ! run clcp 2 1 y V86F 158 0 3 1 C004708C 08000050 2 C0075020 84003000 C0FFF3B8 1 C00A69E8 08000014 3 C00D07F0 80A5A0B3 59ABDE03 59A50E18 1 C00D0DCC 59ABDE03 2 C00D6D6C 84003000 C0FFF3D4 17 C0FFF3B8 90A420C8 58A50E0E 92A420C8 8CA57400 FFFFFE0C 84003000 C0075028 80A560B3 3205200C 59A50901 82A560B3 90A56088 3205200C 84003000 C00D6D74 84003000 C00D6D80 0 CEB4D779 3 0 ----- End Script ----- III. Patch file for use with IBM StorWatch MSS Specialist Client's Update Software feature. Extract the following to filename PATCH_V86F-3_INSTALL.WB_DATA and transfer to the Client host. Specify it in the 'File to load' box from the IBM StorWatch MSS Specialist Update Controller Software screen as selected via the 'Storage' menu option. ----- Begin IBM StorWatch MSS Specialist Script ----- !Sparing size, Save_Config, UA buffer loss (c) DEC 12-Sep-2001 ! 1 V86F 158 0 3 1 C004708C 08000050 2 C0075020 84003000 C0FFF3B8 1 C00A69E8 08000014 3 C00D07F0 80A5A0B3 59ABDE03 59A50E18 1 C00D0DCC 59ABDE03 2 C00D6D6C 84003000 C0FFF3D4 17 C0FFF3B8 90A420C8 58A50E0E 92A420C8 8CA57400 FFFFFE0C 84003000 C0075028 80A560B3 3205200C 59A50901 82A560B3 90A56088 3205200C 84003000 C00D6D74 84003000 C00D6D80 0 CEB4D779 ----- End IBM StorWatch MSS Specialist Script ----- IV. Patch Deletion Script for use with MSS Storwatch Specialist Client'S Update feature. Extract the following to filename to PATCH_V86F-3_DELETE.WB_DATA and transfer to the Client host. Specify it in the 'File to load' box from the IBM StorWatch MSS Specialist Update Controller Software screen as selected via the 'Storage' menu option. ----- Begin Script ----- ! V86-3 patch deletion (c) DEC 12-Sep-2001 ! 2 V86F 3 ----- End Script -----