Final Release of Patch V85P-5 Only applicable to V85P-1 Code Build Stream Pre-requisite patches V85P-2, V85P-3, V85P-4 must be installed prior to this patch. Note: You CANNOT install this patch into V85P-0 build. *************** COMPAQ COMPUTER CORPORATION – DISCLAIMER ************** * In accordance to Compaq's commitment to maintain the highest level * * of customer satisfaction, this patch is being provided to customers * * who have purchased the referenced Storageworks product that is * * currently covered by one of Compaq's extensive warranty plans and * * is also provided to those customers not yet underCompaq's extended * * warranty plan as a courtesy. The availability of this patch is in * * no way an obligation by Compaq to continue this practice in the * * future. * *********************************************************************** ****************************** WARNING ******************************** * * * - Please be sure to cut and paste EXACTLY as indicated. Any * * addition or subtraction of pertinent patch data will mean the * * patch will not load due to a checksum failure and the controller * * will remain at it's original version. * * * * - As always, any critical data should be backed up prior to * * performing any updates. * *********************************************************************** PATCH V85P-5 Patch Title: Forced error set on recovered error during reconstruct HSOF Version: HSG80 V85P Patch Number: 5 Date: 12-March-2001 I. Patch Description: Problem Symptoms: Software application failures may occur as a result of forced error status encountered upon reads to Raid 5 storage units. When a file is read that contains a forced error status, the read operation will fail. Problem statement: When a storage set is under reconstruct, if a disk device in the storage set encounteres a recovered error on a disk, the unit will be marked with forced error on that file. There is no indication of this happening until the host read accesses that file. Title: Forced error set on recovered error during reconstruct Version: V85P Length: 129 Patch Type: 0 Patch Number: 5 Count: 2 Address: C0053088 Value[ 0]: 84003000 Value[ 1]: C0FFF400 Count: 24 Address: C0FFF400 Value[ 0]: 32052044 Value[ 1]: 330D2038 Value[ 2]: 88A42056 Value[ 3]: 90AC2068 Value[ 4]: 59A54014 Value[ 5]: 59BD0C05 Value[ 6]: 8CB42044 Value[ 7]: 90AD9D17 Value[ 8]: 58A7D094 Value[ 9]: 58A54194 Value[ 10]: 92A59D17 Value[ 11]: 5CA01E01 Value[ 12]: 82A420F5 Value[ 13]: 5CA01E02 Value[ 14]: 82A420F4 Value[ 15]: 88A4207C Value[ 16]: 92A460E4 Value[ 17]: 98A460D8 Value[ 18]: 59A05014 Value[ 19]: 92A460D8 Value[ 20]: 32AD0008 Value[ 21]: 0A000000 Value[ 22]: 84003000 Value[ 23]: C00530E0 Count: 0 Verification: BE0EE21A II. Patch Installation Script for use with a host to CLI Utility Extract the following script to file PATCH_V85P-5.script. Submit script to CCL via Command Scripter utility. ----- Begin Script ----- ! ! Forced error set on recovered error during reconstruct ! run clcp 2 1 y V85P 129 0 5 2 C0053088 84003000 C0FFF400 24 C0FFF400 32052044 330D2038 88A42056 90AC2068 59A54014 59BD0C05 8CB42044 90AD9D17 58A7D094 58A54194 92A59D17 5CA01E01 82A420F5 5CA01E02 82A420F4 88A4207C 92A460E4 98A460D8 59A05014 92A460D8 32AD0008 0A000000 84003000 C00530E0 0 BE0EE21A 3 0 ----- End Script ----- III. Patch Installation Script for use with SCU (TRU64 only) download utility: Extract the following script to PATCH_V85P-5.TXT and execute it using SCU. ----- Begin Script ----- ! ! Forced error set on recovered error during reconstruct ! run clcp 2 1 y V85P 129 0 5 2 C0053088 84003000 C0FFF400 24 C0FFF400 32052044 330D2038 88A42056 90AC2068 59A54014 59BD0C05 8CB42044 90AD9D17 58A7D094 58A54194 92A59D17 5CA01E01 82A420F5 5CA01E02 82A420F4 88A4207C 92A460E4 98A460D8 59A05014 92A460D8 32AD0008 0A000000 84003000 C00530E0 0 BE0EE21A 3 0 ----- End Script ----- IV. Patch Deletion Script for use with SCU (TRU64 only) download utility: Extract the following script to PATCH_V85P-5_DELETE.WB_DATA and execute it using SCU. ----- Begin Script ----- ! Forced error set on recovered error during reconstruct (c) DEC 26-Feb-2001 ! 2 V85P 5 ----- End Script ----- V. Patch file for use with SWCC Client's Update Controller Software feature. Transfer the attached file PATCH_V85P-5_INSTALL.WB_DATA to the Client host and specify it in the 'File to load' box from the SWCC Update Controller Software screen as selected via the 'Storage' menu option. ----- Begin SWCC Script ----- ! Forced error set on recovered error during reconstruct (c) DEC 26-Feb-2001 ! 1 V85P 129 0 5 2 C0053088 84003000 C0FFF400 24 C0FFF400 32052044 330D2038 88A42056 90AC2068 59A54014 59BD0C05 8CB42044 90AD9D17 58A7D094 58A54194 92A59D17 5CA01E01 82A420F5 5CA01E02 82A420F4 88A4207C 92A460E4 98A460D8 59A05014 92A460D8 32AD0008 0A000000 84003000 C00530E0 0 BE0EE21A ----- End SWCC Script -----