PATCH V85P-3 Patch Title: Correct credit management ACS Version: V85P Patch Number: 3 Date: 13-December-2000 I. Patch Description: This patch will ensure that HSG80 Controllers Crashing With Last_Failure Code 02F60103 And 43130100 under condition whereby unit attentions are logged inappropriately to the CCL. NOTE =========================================================== NOTE NOTE: NOTE NOTE: Patch is ONLY applicable to V85P-1 Code Build Stream NOTE NOTE: Patch V85P-2 IS A prerequisite and must be applied to NOTE NOTE: the V85P-1 Code Build Stream NOTE NOTE: You CANNOT install this patch into V85P-0 build. NOTE NOTE: NOTE NOTE =========================================================== NOTE II. Patch in text form: Extract the following text to PATCH_V85P-3.TXT and send to customers entering the patch by hand. ----- Begin text ----- Title: Don't log UA to only CCL Version: V85P Length: 24 Patch Type: 0 Patch Number: 3 Count: 1 Address: C0046DBC Value[ 0]: 08000050 Count: 0 Verification: 5766C3DA ----- End text ----- III. Patch Installation Script for use with FIBSCRIPT utility: Extract the following script to PATCH_V85P-3.SCRIPT and execute it using FIBSCRIPT. ----- Begin Script ----- ! !Don't log UA to only CCL ! run clcp 2 1 y V85P 24 0 3 1 C0046DBC 08000050 0 5766C3DA 3 0 ----- End Script -----