Fixes Defects: PM36036,PM36364,PM40822,PM29393,PM32645,PM21294,PM35059,PM31854,PM35941,PM36508,PM30980,PM07684,PM32289,PM26661,PM06172,PM08207,PM09930,PM36839,PM39040,PM12195,PM17833,PM35457,PM26962,PM28997,PM35806,PM34522,PM37992,PM38589,PM36843,PM34196,PM29078,PM34795,PM34104,PM36778,PM37156,PM17962,PM34435,PM30658,PM29391,PM25408,PM33820,PM29406,RATLC01334785,RATLC01334783,RATLC01334797,RATLC01334798,RATLC01334799,RATLC01327458,RATLC01311027,RATLC01334050 This patch contains the following software changes: PM36036: Fixes a performance issue in the ClearCase Remote Client where clicking on the MyActivities node (when CCRC is ClearQuest-enabled) produces a degraded performance when the list of activities is large. PM36364: Fixes a problem in the integration between Base ClearCase and ClearQuest where sending a request to the ClearQuest Web client using the CQWebjava.pm returns the results in blocks of 100 records and every 100th record is sent twice. PM40822: Fixes a ClearCase MVFS problem encountered when logged into a non-Global zone on Solaris 10 platforms, where getcwd() randomly returns EACCES errors against a directory outside of a VOB or within a VOB. For more information, see http://www.ibm.com/support/docview.wss?uid=swg21501830 PM29393: Fixes a ClearCase MVFS problem encountered when logged into a non-Global zone where getcwd() randomly and sporadically returns EACCES errors when calling /bin/pwd in parallel. PM32645: Addresses a ClearCase Mainframe Connectors issue where the -T value is not parsed correctly and is ignored by rccbuild connectors. PM21294: Resolves a problem in the IBM Install Manager where a Rational ClearCase installation fails if the user enters an SMTP address containing more than 6 characters in the last segment (such as user@SMTP.domain1) in the "SMTP Mail server host name" text box. PM35059: Addresses a ClearCase Remote Client issue on Linux platforms where creating a new file with the same name as an existing element, by performing a New > File operation in the ClearCase Details view, overwrites the contents of that element. PM31854: Fixes a ClearCase problem on UNIX platforms where removing a remote scheduled job prior to running a "cleartool space -view -update" command results in an infinite loop. PM35941: Addresses a ClearCase issue where the CLEARCASE_ACTIVITY environment variable contains no information during a checkin process. PM36508: Fixes ClearCase MultiSite problems where (1.) a replicated VOB fails to import an unreserved oplog after a ClearCase upgrade operation and (2.) a file checked out as unreserved and non-mastered is synchronized to a remote replica and future attempts to request mastership of the file fail with an error stating that "At least one checkout prevents the request." PM30980: Fixes a ClearCase problem where clearmake erroneously reports "interference from another process" errors when multiple build scripts from multiple, simultaneously-started, non-parallel builds spawn large numbers of short-lived child processes. PM07684: Resolves a ClearCase installation issue on UNIX platforms where the IBM Installation Manager logs were removed during an uninstall process, even if the uninstall failed. PM32289: Addresses an issue in the ClearCase Remote Client where attempting to move a child folder from one parent folder to another twice (because the user did not see it appear in the destination folder after the first move) produces an error message stating that the move did not occur. PM26661: Fixes a ClearCase Mainframe Connectors problem where users encounter an error during Impact Analysis update at compile that reads: fopen("dd:CLUSTER"...) failed. PM06172: Addresses a ClearQuest Reporting issue where Report Server does not display a check box for Boolean parameters but displays a text box instead. PM08207: Fixes a problem in the ClearCase Remote Client command line interface where the rcleartool "checkin" command does not change the checkin comments when the comments are specified using "-c". PM09930: Fixes a problem in the ClearCase Remote Client command line interface where running an rcleartool "co –reserve" command performs the checkout as unreserved. PM36839: Fixes a ClearCase problem where the MVFS fails to allocate a VOB mnode and the file system calls made by a calling application can return ENOMEM errors, causing build failures. PM39040: Addresses an issue in the ClearCase Mainframe Connectors where the VBM dataset format was producing any of the following errors: RCCE-027, RCCE-045, RCCE-123. PM12195: Fixes a ClearCase MVFS problem on Linux platforms where the /etc/mtab mount table could become corrupted when mounting ClearCase VOBs in high volume environments due to the locking protocols used by MVFS. PM17833: Fixes a ClearCase problem encountered on HP-UX platforms where the clearmake build audit process is unable to get the write time of an object, causing clearmake builds to fail sporadically with an error message that reads, "abe: Error: Unable to get modification time for written object." PM35457: Fixes a ClearCase Mainframe Connectors problem where a temp data set is not freed in the current step for reuse in the following step. PM26962: Resolves a ClearCase Mainframe Connectors problem where users are unable to delete records from an IA VSAM database. PM28997: Corrects a ClearQuest installation problem where the order of license servers in the Rational Common Installer is not preserved and the servers may not be configured in the same order as they were entered during installation. PM35806: Addresses a ClearCase MVFS issue encountered on HP-UX platforms that causes delays and MVFS log errors when dynamic views are first registered within MVFS upon execution of cleartool commands. PM34522: Addresses an issue in the ClearCase Remote Client where a user is unable to remove (rmname) an element if that element is explicitly specified in the view’s load rules. PM37992: Fixes a ClearCase problem where using a Hudson client can produce sporadic db_VISTA -906 errors. PM38589: Fixes a ClearCase UCM defect where composite baselines were being created unnecessarily when no changes had been made in the stream. PM36843: Fixes a ClearCase problem where a cleartool "annotate" command encounters lengthy version comments and returns an error message stating: "Supplied buffer is too small." PM34196: Corrects a problem in the Rational ClearCase MainFrame client where TSOC cannot parse the E.D file with SERVER_CODEPAGE IBM-1364 because it is not correctly handling the escape character backslash ("\") which is displayed as the Korean Won currency mark. PM29078: Addresses a ClearCase Mainframe Connectors issue where the process of running a remote build and sending large SYSPRINT output in BCL (in excess of 11M) back to a PC fails to return the file because the process requires too much REGION size when transferring SYSPRINT with code page translation. PM34795: Fixes a ClearCase Mainframe Connectors problem where a ccbuild job hangs without feedback when a BCL file is larger than 16K. PM34104: Resolves a ClearCase MVFS problem that causes a memory leak on Solaris platforms when non-ClearCase clients access an ncaexported view/vob pairing. PM36778: Addresses a ClearCase MultiSite issue where moving a version from the change set of one UCM activity to the change set of another UCM activity does not require mastership of the activities or the version. PM37156: Addresses a ClearCase Remote Client issue where the performance time of various operations in the CCRC user interface degrades as projects and data sets grow larger. PM17962: Resolves a ClearCase and ClearQuest installation issue where selecting port number 12080 in the IBM Installation Manager while installing ClearCase or ClearQuest causes the installation to fail. PM34435: Fixes a problem in the ClearCase SCM Adapter where checking out a file with a version-extended name that is longer than 470 characters causes Eclipse to crash. PM30658: Fixes a problem in the ClearCase integration with Microsoft Visual Studio 2010 where attempting to exclude a directory from a project produces a message that states, "Before removing this folder, you must remove its contents." PM29391: Addresses a ClearCase performance issue encountered when browsing a directory in ClearCase Explorer on a Windows 7 host, where ClearCase specifies that cleartext is constructed for the visible version of every file element in the directory. PM25408: Fixes a ClearCase problem encountered when refreshing view shortcuts in the ClearCase Explorer where users may receive the following error: "The parameter is incorrect." PM33820: Fixes a problem in the ClearCase Remote Client where the Repair Discordance option does not work if the parent directory or the element name contains a Chinese character. PM29406: Addresses a ClearCase Mainframe Connectors issue where the -n -c option of RCCBUILD has no effect on the execution of BCL, instead of terminating the job when the -n -c check is failed. RATLC01334785: Fixes a ClearCase Mainframe Connectors problem where users see no data in ClearCase elements in the TSO Client after changing the file-mapping in ED. RATLC01334783: Fixes a ClearCase Mainframe Connectors problem where a compile fails during impact analysis with an S322 error code. RATLC01334797: Addresses a ClearCase Mainframe Connectors issue where Option 1.4 in the TSO Client does not associate a CR with the view selected in Option 1.3 until the user performs a checkout. RATLC01334798: Fixes a ClearCase Mainframe Connectors problem where TSCENV data sets with a large number of EDs (in excess of 100) causes the TSO Client to fail with the following error message: "Number of dataset allocations for the session exceeded." RATLC01334799: Addresses a ClearCase Mainframe Connectors performance issue where a slow startup time for the TSO Client affects Clist operations. RATLC01327458: Addresses a ClearCase Mainframe Connectors issue on the IBM z/OS platform where Build Control Language (BCL) condition code handling is only checked for the previous step instead of all previous steps. RATLC01311027: Addresses a ClearCase type manager issue that required all versions of the same element to use the same character encoding. RATLC01334050: Addresses a ClearCase Mainframe Connectors issue on IBM z/OS platforms where files in the VOB contain the invalid symbol "ˆM" which causes the BCL file to return the following error: "Syntax error. Build script statement exceeds 80 bytes."